TCG 3016 V16
TCG 3016 V16
S = High Density
1,000 kW el
Outstanding price-performance ratio: Highest-in-class power density. High stress tolerance, optimum availability, and long useful life.
- Output: 1,000 kWel and 1,100 kWth
- Low investment and service costs, high electrical efficiencies of up to 41.1 percent
- Lowest-in-class lube oil consumption, high power density, small setup space
MWM Gas Engine TCG 3016 V16 (S = High Density) – One Megawatt.
More Performance at an Unbeatable Price.
- For all natural gas applications with 50 Hz networks
- Output: 1,000 kWel and 1,100 kWth
- Low investment and service costs, high electrical efficiencies of up to 41.5 percent
- High power density, small setup space
- Low plant investment costs ensure fast payback
- Lowest-in-class lube oil consumption, easy oil management through longer oil change intervals and integrated lube oil tanks
On this page
Description – MWM Gas Engine TCG 3016 V16 S
Performance Data – MWM Gas Engine TCG 3016 V16 S
Specifications and Service Intervals – MWM Gas Engine TCG 3016 V16 S
Brochure – MWM Gas Engine TCG 3016 V16 S
Description – MWM Gas Engine TCG 3016 V16
S = High Density
Outstanding Price-Performance Ratio
- Low investments and service costs, high electrical efficiency of 41.5 percent
- Fast payback period of CHP (combined heat and power) plant due to lower investment costs
- Compact genset with high power density and small setup space thanks to integrated lube oil tanks
- Vibration-decoupled base frame (flanged genset concept) for lower installation costs and reliable operation
Higher Availability and Longer Useful Life
- Optimized combustion through improved charging system
- TCG 3016 V16 (S = High density): smoothly running, low-vibration genset with reduced peak pressure fluctuations
- Improved turbo charger with longer maintenance intervals and wider suction air temperature window for a wide range of deployment options
Optimized Lube Oil Management
- Lowest-in-class lube oil consumption: 0.1 g/kWhel
- The large integrated lube oil volume and the low lube oil contamination for significantly longer oil change intervals and easier oil management
TPEM (Total Plant & Energy Management) – The New System for MWM Solutions
- Integrated system for genset, auxiliary genset, and plant control
- Intuitive use, local or via integrated remote access
- Well-structured, detailed status reports and log views
- Can be switched from parallel to isolated operation including network synchronization/load balancing
Further information on TPEM: Total Plant & Energy Management
Performance Data – MWM Gas Engine TCG 3016 V16
S = High Density
Natural gas applications, NOx ≤ 500 mg/Nm3*
TCG 3016 V16 S = High density | ||
---|---|---|
Engine type | 50 Hz | |
Electrical output | kW | 1,000 |
Medium effective pressure | bar | 23.5 |
Thermal output ± 8% | kW | 1,123 |
Electrical efficiency | % | 41.5 |
Thermal efficiency | % | 46.6 |
Overall efficiency | % | 88.1 |
Power to heat ratio ** | 0.89 |
* With 5% O2 and dry exhaust gas
** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.
Specifications and Service Intervals – MWM Gas Engine TCG 3016 V16
S = High Density
Adimensions and Weight
TCG 3016 V16 S = High density | ||
---|---|---|
Engine type | 50 Hz | |
Bore / Stroke | mm | 132/160 |
Displacement | dm3 | 35.0 |
Speed | min-1 | 1,500 |
Mean piston speed | m/s | 8.0 |
Length | mm | 4,200 |
Width | mm | 1,780 |
Height | mm | 2,150 |
Dry weight genset | kg | 8,560 |
Service intervals
First Service * | Spark plug change | Cylinder head inspection | General overhaul | |
---|---|---|---|---|
Natural gas | 2,000 Oh *** | 4,000 Oh | 32,000 Oh ** | 64,000 Oh |
* “after commissioning (E10)”
** “at the latest”
*** “High gas quality”
Brochure – MWM Gas Engine TCG 3016 V16
S = High Density
Further information on the TCG 3016 V16 (S = High density) gas engine is available here.
MWM Gas Engine TCG 3016 V16 S = High density
Click this brochure to access the digital publishing platform issuu.com. This website is governed by the issuu Privacy Policy.
All languages on issuu: DE | EN | FR | RU | ES | TR | CN
Download PDF: DE | EN | FR | RU | ES | TR | CN
MWM Digital Power
With its comprehensive digital power plant control TPEM (Total Plant & Energy Management), MWM revolutionizes the control standard for energy solutions.
Gas engines & Products
Container Cogeneration Plant
Compact modules for the TCG 3016, TCG 3020 and TCG 2020 gas engines. Complete turnkey systems for special applications.
Gas Engine TCG 2020
Best electrical and thermal efficiency in its class. All gas types: natural gas, biogas, mine gas, landfill gas, sewage gas.
TCG 2032
High reliability. Low operating costs. Gas types: natural gas, landfill gas, sewage gas, mine gas, coke oven gas. Mainly used in large IPP projects with up to 100 MWel.
Gas Engine TCG 3016
New development – greatly reduced operating and installation costs and fully digitized power plant control.
MWM Service Tutorial Video #1
Do it the smart way
Basic Maintenance Tips
Episode 1: Spark Plug Replacement
MWM Service Tutorial Video #2
Do it the smart way
Basic Maintenance Tips
Episode 2: Valve Clearance Adjustment